Issue0000081: Caps close to blow up
IDPSU: 400-5397-01
Tagspower

Activities

Tak-MK

2024-06-30 15:53

administrator   ~0000268

SN: 934917

Tak-MK

2024-06-30 15:54

administrator   ~0000269

Top right cap is swollen.
IMG_8846.JPG (3,155,853 bytes)   
IMG_8846.JPG (3,155,853 bytes)   

Tak-MK

2024-06-30 15:54

administrator   ~0000270

Replaced 10V 2200uF cap.

Tak-MK

2024-06-30 15:54

administrator   ~0000271

Put a galvanized coating after cleaning the rusted part a bit.
IMG_8849.JPG (4,225,639 bytes)   
IMG_8849.JPG (4,225,639 bytes)   
IMG_8850.JPG (5,123,703 bytes)   
IMG_8850.JPG (5,123,703 bytes)   

Tak-MK

2024-06-30 15:55

administrator   ~0000272

Voltages are correct.
Fan doesn't spin but I don't know if it should be always on or not.

Issue History

Date Modified Username Field Change
2024-06-30 15:53 Tak-MK New Issue
2024-06-30 15:53 Tak-MK Tag Attached: power
2024-06-30 15:53 Tak-MK Note Added: 0000268
2024-06-30 15:54 Tak-MK Note Added: 0000269
2024-06-30 15:54 Tak-MK File Added: IMG_8846.JPG
2024-06-30 15:54 Tak-MK Note Added: 0000270
2024-06-30 15:54 Tak-MK Note Added: 0000271
2024-06-30 15:54 Tak-MK File Added: IMG_8849.JPG
2024-06-30 15:54 Tak-MK File Added: IMG_8850.JPG
2024-06-30 15:55 Tak-MK Note Added: 0000272
2024-06-30 15:55 Tak-MK Assigned To => Tak-MK
2024-06-30 15:55 Tak-MK Status Queued => Done
2024-06-30 15:55 Tak-MK Resolution Shelved => Repaired